The liquid level is normal, the whole machine still can not operate, why?
- If your equipment uses a three-rod electrode type for low-level protection, please check whether you use pure water for operation, pure water is a bad conductor, resulting in the three-rod electrode cannot be inducted, please replace it with tap water and try again.
- If your equipment uses a float type of low-level protection, please check for foreign matter or crystalline matter to block it and remove it; If the specific gravity of the plating solution is different from that of the previous use, so please check that the float cannot be used.